Consulting · Oncology · Brand-independent

When every drop counts

Brand-independent consulting on closed system transfer devices (CSTD) for hospitals and pharmacies. We clarify whether using one makes sense in your facility, why, which perspectives need to be considered and which system fits your workflows in preparation and administration.

From vial to vein

5 open transitions. Wherever the system opens, aerosols and drops can escape. Even when the work is done carefully.

System boundary closed. From the first puncture to disconnection the drug stays inside the system, and nothing gets in from outside.

  1. 1

    Vial puncture

    Pressure equalizes through room air. Aerosols possible.

    Pressure equalization without air exchange with the surroundings.

  2. 2

    Transfer

    Microdroplets on needle and septum.

    Closed coupling between vial and syringe.

  3. 3

    Venting the syringe

    Air and drug escape at the tip.

    Venting inside the closed system.

  4. 4

    Infusion connection

    Drops and leaks when injecting into the bag and connecting.

    Drip-free connection to bag and line.

  5. 5

    Disconnection & disposal

    Drops and residual volume at open ends.

    Drip-free disconnection, even when therapy is interrupted.

Exposure arises along the entire process chain. Compounding · Transport · Administration · Disposal
Why quattramed Consulting

We know the problems, the rules and the systems.

Risks

Real problems and hazards

Exposure routes, contamination and consequences, from compounding to disposal.

Regulation

Legal framework

EU directive, German Hazardous Substances Ordinance, TRGS 525, USP <800> and NIOSH, put into context for your facility.

Systems

Differences across brands

Test evidence, pressure equalization and handling of the common CSTDs compared.

Departments

Tailored to every role

Pharmacy, nursing, occupational safety, infection control, QM, purchasing and management.

The oncology paradox

Patient protection is secured by technology. Staff protection mostly only by organization.

For the patient

Every unnecessary exposure is avoided.

  • Dosing by body surface area or target value, checked several times
  • Processes against incorrect administration, overdosing and medication errors
  • Supportive therapy according to the German S3 guideline to counter side effects
For staff

The same drugs are handled every day.

  • Compounding, transport, administration and disposal, often several times per shift
  • Protection mainly through training, cleaning instructions and PPE
  • Spill kits and wipe samples only come into play once contamination has occurred
  • At the bedside there is no safety cabinet anymore

When technical prevention is possible, acceptance needs explaining.

Survey of oncology nurses in Germany · 2025
1 in 3
33.75%

nurses report symptoms that they attribute to handling cytotoxic drugs, mainly skin reactions, headaches and changes in taste.

35%

of exposures happen during administration. That makes it the most frequent point in time, exactly where no safety cabinet protects.

80 / 60

80% of facilities have SOPs. But only 60% of nurses use gloves resistant to cytotoxic drugs.

Naegele M. German cancer nurses and occupational exposure to cytotoxic drugs: A cross-sectional study with a mixed-methods approach. Eur J Oncol Nurs. 2025;79:103014. View the study (sciencedirect.com)

STOP principle

Physics cannot be trained away.

At puncture, vials are under positive or negative pressure. Open systems equalize it through room air. This creates aerosols, or air with particles is drawn in. It happens even when the work is flawless.

Liquid under pressure+human handling=Probability of release ≠ 0
Training can
  • Raise awareness
  • Shorten reaction time
  • Reduce errors
Training cannot
  • Eliminate pressure differences
  • Prevent aerosol formation
  • Physically rule out leaks

Training reduces errors. A closed system transfer device reduces release. The two work on different levels.

S

Substitution

Replace the hazardous substance. Generally not possible with cytotoxic drugs.

CSTD
T

Technical measures

Safety cabinet, isolator and closed system transfer devices. They work regardless of behavior.

O

Organizational measures

SOPs, training, cleaning instructions, spill kits, monitoring.

P

Personal protective equipment

Gloves, protective gowns, respiratory protection. The last barrier.

Isolator = compounding barrier in the pharmacy CSTD = transfer barrier all the way to the patient
Regulations & standards

The framework in which CSTDs are assessed.

There are clear guardrails for the preparation and administration of hazardous drugs. What matters is how they are implemented, justified and documented in your facility.

EU

Directive 2004/37/EC

If a CMR substance cannot be replaced, it must be manufactured and used in a closed system as far as technically possible (Art. 5).

Germany

Hazardous Substances Ordinance (GefStoffV)

Hierarchy of protective measures: technical before organizational and personal measures (STOP principle, section 7).

Germany

TRGS 525

Hazardous substances in healthcare facilities. Names transfer systems as suitable aids against release.

Germany

Occupational Safety and Health Act (ArbSchG)

Protective measures must take the state of the art into account (section 4).

USA

USP <800>

CSTDs are required when administering antineoplastic drugs, where the dosage form allows, and recommended for compounding.

USA

NIOSH and FDA product code ONB

NIOSH maintains the list of hazardous drugs and has drafted a test protocol for CSTDs. ONB is the US product class for closed system transfer devices.

Brief overview, not exhaustive. The assessment for your facility does not replace legal advice.

Containment

Tight does not mean closed.

The term CSTD is not clearly defined in the European legal framework. Many systems are called "closed". What matters is what their test evidence actually proves.

Low protection

Open system

Needle and syringe. Retains neither vapors nor aerosols. Spills and needlestick injuries are possible.

Moderate protection

Semi-closed system

Spike with Luer connection or needle-free connector. Mechanically tight, but does not reliably retain vapors and aerosols. Drops at connection points remain possible.

High protection

CSTD with proof of containment

No escape of drug, vapor or aerosol. No ingress of germs and particles from the surroundings. Drip-free disconnection.

What a test report shows and what it does not

Engineering tests prove function. Only a containment test shows whether a system retains hazardous drugs. In the consultation we go through the test reports of the systems relevant to you, across manufacturers.

Request a system comparison
TestProves
Pressure or air tightnessComponents hold pressure without leaking. Mechanically tight.
Microbial tightnessBacteria do not get in. A microbiological barrier is not a barrier against cytotoxic drugs.
Ethanol vapor testLow evaporation of ethanol. Ethanol is not a cytotoxic aerosol.
Comparative test without a limit valueDifferences between systems, but no proof of containment.
Containment test, e.g. following the NIOSH protocolRetention of hazardous drugs and their vapors.
Perspectives

One system, seven points of view.

The assessment is often made in the pharmacy, exposure mainly affects nursing, and the decision is made in purchasing and management. We look at CSTDs from each of these roles and bring them to one table.

Pharmacy

Precision, asepsis and efficiency

Outcome

Faster, safer compounding with a validated standard of protection.

  • No pressure equalization through room air, no "pop" at puncture
  • Substance-tight transfer prevents air contact and aerosol formation
  • Fewer steps, less material used, faster workflows
  • Use beyond cytotoxic drugs: antibiotics, antivirals, biologics
Our question to you

Is the system boundary after vial puncture deliberately defined in your processes?

Nursing

Safety where closeness happens

Outcome

Protection of nurse and patient without extra effort.

  • No drops, no vapor, no odor during administration
  • Safe connecting and disconnecting, even when the patient is mobile (restroom, CT)
  • No contamination of skin or clothing after bolus administration
  • Uniform handling instead of open systems and workarounds
Our question to you

Where do your nurses see drops today when disconnecting?

Occupational safety & infection control

What does not escape does not have to be cleaned up

Outcome

A verifiable standard of protection, visible in every wipe sample.

  • Technical measure first, as the STOP principle requires
  • Markedly lower surface contamination according to studies
  • Combined protection for people and surroundings
  • Fewer cleaning cycles, cleanliness that can be validated
Our question to you

Which technical measures does your risk assessment provide for administration?

Quality management & regulation

What is documented is protected

Outcome

Transparency and legal certainty in every process step.

  • CSTD as a validated protective system, not an accessory
  • Verifiable measure in the QMS, risk assessment and audit
  • A demonstrable state of the art makes audits stable
Our question to you

How do you demonstrate the state of the art today when handling CMR drugs?

Purchasing & administration

Safety pays off

Outcome

Lasting cost-effectiveness with legal protection.

  • Prevention lowers follow-up costs from absences, cleaning and training
  • Less waste thanks to vials punctured in a closed system
  • Fewer consumables and less contaminated waste
  • Procurement actively contributes to compliance
Our question to you

Under which parameters does use pay off for your facility?

Management & legal

Mandatory protection protects management

Outcome

Robust evidence: duty fulfilled, risk minimized.

  • The Hazardous Substances Ordinance requires technical protective measures first
  • Foreseeable risks fall under organizational responsibility
  • Documented CSTD use strengthens the evidence
Our question to you

Should your occupational safety rest on human perfection or on a system that limits release by design?

Patients & the public

Safety you can see and feel

Outcome

Visible safety builds trust in treatment and staff.

  • No contact with toxic drops after bolus administration
  • No risk from open systems during transport or breaks
  • Noticeable hygiene and professionalism
Our question to you

What degrees of freedom would be possible for your patients if the connections were technically secured?

Cost-effectiveness

The biggest cost driver is not the adapter.

Anyone who judges CSTDs by unit price alone overlooks the costs they avoid. These lie in waste, unused residual amounts, the choice of pack size and the organization.

Punctured open

1 vial = 1 dose

The rest is discarded after preparation.

Punctured closed

1 vial = n doses

Residual amounts are used in a controlled way for subsequent preparations.

Waste
Punctured vials do not have to be discarded after a single preparation.
Pack size strategy
Larger, more economical pack sizes only pay off when residual amounts can be used safely.
On-call service
Time-critical preparations can also be carried out in a closed system outside the pharmacy.
Follow-up costs
Less cleaning, monitoring, contaminated waste and absences.
Cost-effectiveness review

Your facility, your figures.

Whether using a CSTD pays off depends on the drug mix, pack sizes, multiple withdrawals and implementation. Model calculations from our practice show clear effects, depending on the facility. We run the numbers with your data.

  • Preparations per drug
  • Dose by BSA or Calvert formula
  • Real pack sizes and market prices
  • Multiple withdrawals only with a closed vial

Under which parameters is use cost-effective for your facility, and do you meet them?

Have cost-effectiveness reviewed
Systems compared

Four building blocks, many names.

Every closed system transfer device covers the same four tasks, for preparation and administration. But manufacturers name their components differently. The comparison shows the common systems at a glance.

Building blockBDPhaSeal™ OptimaSimpliviaChemfort™SimpliviaTevadaptor®EquashieldEQUASHIELD®ICU MedicalChemoLock™Epic MedicalProSeal™Yukon MedicalArisure™
Vial adapterVial Adaptor, preparationProtectorVial AdaptorVial AdaptorVial AdaptorVial SpikeVented Universal Vial AdaptorClosed Vial Adapter
Syringe adapterSyringe Adaptor, preparation & administrationInjectorSyringe Adaptor (Lock)Syringe Adaptor (Lock)Syringe UnitInjectorTransfer InjectorClosed Male Luer
Spike / bag adapterBag & Spike Adaptor, preparationInfusion AdapterBag Adaptor SP / LLSpike Port AdaptorSpike AdaptorBag SpikeBag SpikeDry Spike
Luer lock / patient adapterLuer Lock Adaptor, administrationConnectorLuer Lock AdaptorLuer Lock AdaptorLuer Lock AdaptorPortInjection Site Male Luer Lock-

Component names according to manufacturer information and the US medical device database (FDA product code ONB), without sizes and variants. The mapping describes the function within the system and is not a comparison of equivalence or quality. - = not listed as a separate component in the documents reviewed.

Other manufacturers and systems

  • Texium™ Closed Male Luer (BD)
  • ChemoClave™ (ICU Medical)
  • ToxiSeal™, ZeroClear™ (Epic Medical)
  • Qimono™ (Vygon)
  • Halo® (Corvida Medical)
  • NeoShield™ (JMS)
  • ClickLock™ (Sidam)
  • Closed System Transfer Device (Shinva Ande)

Looking for Chemfort™ or Tevadaptor® from Simplivia?

Chemfort™ includes, among other components, the vial adapter with Toxi-Guard®, the syringe adapter Lock, the bag adapter SP and the LLm adapter. We assess Chemfort™ and Tevadaptor® independently of brands: in comparison with other CSTDs and in relation to your workflows in preparation and administration.

Request a system comparison for your facility

All brand and product names mentioned are trademarks of their respective owners. They are named for context and do not constitute a recommendation. Not exhaustive; not every system is available in Germany.

Consulting

Whether using a CSTD makes sense is something we clarify together.

As an expert conversation, as on-site consulting, as coaching for your project team or as training for your staff: we tailor content and format to your facility and your questions, online or on site at your facility.

quattramed Consulting

CSTD Consulting for Oncology

Together with you we clarify whether using a CSTD makes sense in your facility, why, which perspectives need to be considered and which system fits your workflows.

  • Analysis of your situation from vial to vein
  • Risk analysis for preparation, transport and administration
  • Regulatory assessment and cost-effectiveness
  • Brand-independent system comparison
  • Brand-independent
  • Interdisciplinary
  • Online or on site
Format Online On site
Price on request We prepare an individual quote based on scope and format. Your inquiry is non-binding.
01

Taking stock

A short initial conversation: which drugs and volumes, which workflows, and where is the system boundary after vial puncture defined today?

02

Analysis from vial to vein

Compounding, transport, ward and outpatient clinic. We mark the transitions where the system opens and the protective measures that apply there.

03

Education in-house

Presentation, workshop or training for pharmacy, nursing, occupational safety, infection control and purchasing.

04

Assessment and recommendation

Regulatory assessment, cost-effectiveness based on your figures and a brand-independent system comparison.

05

Support

On request we support trials, coaching of the project team and the changeover.

Terms

From vial adapter to syringe adapter.

Closed system transfer device, CSTD: at its core every system consists of four building blocks. Select one.

Sits on the vial

Vial adapter

also: Vial Adaptor, Vial Spike, Protector

Function

Placed on the vial once and stays there. It punctures the septum and equalizes the pressure without exchanging air with the room. Depending on the system via a filter, a membrane or an expansion volume.

Why it matters

This is the first system boundary. If the vial stays closed after puncture, it can continue to be used in a controlled way.

What to look for

Principle of pressure equalization, matching neck sizes (e.g. 13, 20 and 28 mm), residual volume in the vial.

Sits on the syringe

Syringe adapter

also: Syringe Adaptor, Injector, Syringe Unit, Closed Male Luer

Function

The counterpart to all other adapters. It sits on the Luer lock of the syringe, couples in a closed manner to vial, bag or line and disconnects drip-free.

Why it matters

It accompanies the preparation from compounding to administration. It determines whether connecting and disconnecting stay safe.

What to look for

Number of steps, protection against accidental loosening of the Luer connection, suitability for automated compounding.

Sits in the bag port

Spike / bag adapter

also: Bag Adaptor, Spike Adaptor, Bag Spike, Infusion Adapter, Spike Port Adaptor

Function

Makes the injection port of the infusion bag compatible with the closed system. The drug is added through it and later administered.

Why it matters

The preparation leaves the pharmacy with a closed connection. On the ward nobody has to spike openly anymore.

What to look for

Compatibility with the bag ports used in-house, universal or port-specific spike.

Sits on the line or access

Luer lock adapter

also: Luer Lock Adaptor, Connector, Port, patient adapter, LLm adapter

Function

Closes the patient side at the infusion line, three-way stopcock or catheter. Bolus doses, connecting infusions and disconnecting all run through it.

Why it matters

Administration is the most frequent point of exposure. With this adapter even an interruption of therapy stays closed.

What to look for

Fit with lines and access devices used in-house, dead volume, handling with protective gloves.

Terms relating to CSTDs

Preparation Compounding
Making the ready-to-administer solution in the pharmacy, usually in a safety cabinet or isolator.
Administration
Connecting, administering and disconnecting at the patient. The most frequent point of exposure, without a safety cabinet.
CSTD Closed System Transfer Device
Mechanically prevents drug, vapor or aerosol from escaping and contaminants from the surroundings from entering.
CMR substances
Carcinogenic, germ cell mutagenic or reprotoxic substances. Many cytotoxic drugs are among them.
System boundary
The point at which a closed system becomes open. Without a CSTD this is usually the first puncture of the vial.
Pressure equalization
Puncture and withdrawal change the pressure in the vial. Open systems equalize it through room air, a CSTD via filter, membrane or expansion volume.
Aerosol Microdroplets
Very fine droplets that can form during pressure equalization, venting or disconnection. Mostly invisible.
Containment
Retention of the drug including vapor and aerosol inside the system. Distinguishes a CSTD from a system that is merely tight.
Drip-free disconnection
Separating a connection without liquid remaining on the contact surfaces.
Semi-closed system
For example a spike with Luer connection or a needle-free connector. Mechanically tight, without reliable retention of vapors and aerosols.
Multiple withdrawals
Withdrawing several doses from one punctured vial. Requires a permanently closed, aseptically controlled connection. Shelf life and release are governed by the pharmacy.
Residual and dead volume
Liquid that remains in the vial or in the components and cannot be withdrawn. Affects cost-effectiveness.
Engineering test
Test of mechanical properties such as pressure or microbial tightness. Proves function, but not containment.
NIOSH protocol
Test method drafted by the US occupational safety institute NIOSH for testing the vapor containment of CSTDs.
FDA product code ONB
US product class "Closed Antineoplastic and Hazardous Drug Reconstitution and Transfer System" (21 CFR 880.5440) for systems intended to reduce staff exposure to chemotherapy drugs.
Safety cabinet and isolator
Compounding barrier in the pharmacy. Protects during preparation, but not during transport, administration and disposal.
Spill kit
Emergency kit for cleaning up spilled cytotoxic drugs. Comes into play once contamination has already occurred.
STOP principle
Hierarchy of protective measures under the German Hazardous Substances Ordinance: substitution, technical, organizational and personal measures.
Luer lock
Standardized screw connection on syringes, lines and three-way stopcocks. The interface where CSTD components attach.
Injection port
Port on the infusion bag through which the drug is added. Becomes usable in a closed manner with a bag adapter.
Questions & objections

What we often hear in conversations.

What is a CSTD (closed system transfer device)?

A transfer system that mechanically prevents drug, vapor or aerosol from escaping and contaminants from the surroundings from entering. CSTDs are used mainly with cytotoxic drugs and other hazardous drugs.

When does using a CSTD make sense?

That depends on drugs, volumes, workflows in preparation and administration, existing protective measures and cost-effectiveness. That is exactly what we clarify in the consultation, with a view to pharmacy, nursing, occupational safety, purchasing and management.

Are CSTDs used during preparation or during administration?

Both. During preparation the CSTD protects when puncturing and drawing up. During administration it protects when connecting, during bolus administration and when disconnecting, in other words where there is no safety cabinet anymore.

What is the difference between a vial adapter and a syringe adapter?

The vial adapter stays permanently on the vial and provides pressure equalization. The syringe adapter sits on the syringe and couples in a closed manner to vial, spike or Luer lock adapters.

Which CSTD manufacturers and brands are there?

Among others BD (PhaSeal™ Optima), Simplivia (Chemfort™, Tevadaptor®), Equashield, ICU Medical (ChemoLock™, ChemoClave™), Epic Medical (ProSeal™), Yukon Medical (Arisure™), Vygon (Qimono™), Corvida (Halo®), JMS (NeoShield™) and Sidam (ClickLock™).

Do you also advise on Chemfort™ and Tevadaptor® from Simplivia?

Yes. We advise independently of brands on all common CSTDs, including Chemfort™ and Tevadaptor® from Simplivia, BD PhaSeal™ Optima, EQUASHIELD® and ChemoLock™, and put them into context for your facility.

But we work in a safety cabinet or isolator.

The isolator protects the compounding process. It does not protect pressure equalization at vial puncture outside the cabinet, nor transport, nor administration. Isolator = compounding barrier, CSTD = transfer barrier.

We do not have elevated contamination values.

Not measured does not mean absent. Even with low values the probability of release physically remains. A CSTD lowers it structurally.

We train regularly.

Training addresses behavior; release is caused by pressure differences and system opening. Training reduces errors, a CSTD reduces release. Under the STOP principle the technical measure comes first.

Is the use of CSTDs mandatory?

EU Directive 2004/37/EC requires a closed system for CMR substances that cannot be replaced, as far as technically possible. The German TRGS 525 names transfer systems as suitable aids. In the USA, USP <800> requires CSTDs when administering antineoplastic drugs. This assessment does not replace legal advice.

How is the consulting billed?

We prepare an individual quote based on scope and format before any costs arise. Your inquiry is non-binding.

Inquiry

How does your facility define the system boundary after vial puncture?

Let us look at this along your workflows, ideally across disciplines with pharmacy, nursing, occupational safety, infection control and purchasing. We usually get back to you on the next working day.

Phone · Mon to Fri, 9:00 a.m. to 4:30 p.m.
+49 6821 40282-60
Address
quattramed GmbH · Büchelstraße 5-7 · 66538 Neunkirchen

Your inquiry list

Non-binding. You receive an individual quote before any costs arise.

Sources
  1. Naegele M. German cancer nurses and occupational exposure to cytotoxic drugs. Eur J Oncol Nurs. 2025;79:103014. Open source
  2. Directive 2004/37/EC on the protection of workers from the risks related to exposure to carcinogens, mutagens or reprotoxic substances at work, Art. 5. Open source
  3. TRGS 525 Hazardous substances in healthcare facilities (German technical rule), section 5.3.2.
  4. USP General Chapter <800> Hazardous Drugs - Handling in Healthcare Settings. Open source
  5. NIOSH List of Hazardous Drugs in Healthcare Settings, 2024. Open source
  6. FDA product code ONB, 21 CFR 880.5440.

Specialist information for healthcare professionals. quattramed Consulting advises independently of brands.